Skip to main content
Frigidaire Dishwasher Error Codes
88 error codes for Frigidaire dishwasher models. Each links to the full diagnostic procedure from the service manual.
CodeDescription
CdClose dishwasher doorCEMalfunction error code displayed when the dishwasher experiences a fault…CLDoor is openE:00No errors stored in memory.E:01Faulty pump relay on the power module.E:02Faulty heater relay on the power module.E:05Faulty water switch relay; water switch runs continually.E:06Door latch Hall sensor not detected; dishwasher won't run and Clean LED is…E:08Heat pump detects low water level; dishwasher runs without heating.E:09Faulty heater circuit (open circuited) on the heat pump.E:11NTC or NTC wiring harness error; dishwasher not heating.E:13Incoming water too hot (>75°C / 167°F); dishwasher runs without heat pump…E:15Float switch activated; water doesn't fill and drain pump runs…E:17Faulty water softener regeneration valve; water softener doesn't regenerate.E:20Faulty heat pump motor winding; wash cycle abruptly ends with Clean/Sanitized…E:21Heat pump is blocked/clogged.E:23Faulty drain pump.E:24Dishwasher won't drain; drain pump is blocked or drain hose obstruction.E:25Drain pump cover missing or loose, preventing pressure build-up; drain pump…E:26Faulty water switch; water switch runs continually.MyPros+ Max
Get the full diagnostic procedure for any Frigidaire dishwasher error code.
- Step-by-step tests with expected resistance, voltage, and continuity values
- Wiring diagram references and connector pinouts
- Verified part numbers when replacement is required
Get started
$29/month · Cancel anytime · Or $9.95 3-day pass
E:27Under-voltage; low supply voltage to dishwasher.E:28Aqua sensor not properly calibrated; aqua sensor doesn't run during wash cycle.E:29Under/overvoltage condition on supply voltage.E:30Over-voltage; high supply voltage to dishwasher.ErMembrane switch failure; the control detects that any pad on the membrane…ER/CEConfiguration Error.ER/ERSwitch Failure.ER/uFFan not running.ER/uoVent will not close.HdIndicates a water heat delayHOIndicates a water heat delay (alternate display); the control is delaying the…hsThe control has sensed a problem with the Hall effect sensor in the wash motor.i00Low mains voltage detectedi1Longer inlet timei10Water tap closedi11Water tap closed during dynamic fillingi20Fails to draini30Water detected from aqua control sensori4Unit leakingi41No pressure sensor signali42Calibration invalidi43Pressure sensor signal too highi44Pressure sensor signal too lowi45Calibration invalidi46Calibration invalidi51Asynchronous washing motor problemi52WP BLDC motor abnormal high current detectedi53WP BLDC motor over currenti54WP BLDC motor will not follow / rotor is lockedi55DC Link overvoltagei56DC Link under voltagei57MCB Vbat voltage plausibility / ADC Faulti58WP motor plug connection detected wrong based on motor current measurements…i59WP current read ADC faulti5AOver temperature or overloadi5BWP/DP current plausibilityi5CDP BLDC motor abnormal high current detectedi5DDP BLDC motor high currenti5EDP BLDC motor will not follow / rotor is lockedi5FDP motor plug connection detected wrong based on motor current measurements…i60Heating element problemi61Heating over temperaturei70NTC sensor value out of rangei80Auto door opener malfunctioni81Auto door opener warningi91Checksum MCFi92Checksum CCFi93Checksum UIDATAi94UIDATA version mismatchi95UIDATA checksum mismatchiB0Turbidity sensor problemiC0User interface communication problemiC1MACS bus communicationiC2ADSI communicationiC3Communication between the power board and Motor Control Board does not start.iD0No tacho signaliD1Critical tacho signaliE0Flow controller position problemiF0Overfilling detectediF1High water levelLORinse aid level is low; appears at end of cycle on models with a STATUS window…OPTION LED's FlashingAll option LEDs flashing indicates a power failure has occurred.PFPower failurerAThe control has sensed a problem with the reed switch in the rinse aid…STATUS LED's FlashingThe STATUS LEDs that are lit when the door is opened will flash, indicating the…tuThe control has sensed a failure in the turbidity (soil) sensor while in the…uFIn the dry mode, the control does not receive proper feedback from the vent…uoThe control does not receive proper indication that the vent is closed; after 5…