Model reference
GE PFQ97HS
Washer
1 document79 error codes2 service modes
Available documentation
Service Manual
- GE All in one PFQ97HS 31 Service Manual2 pg
MyPros+ Max
Diagnose your GE PFQ97HS.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (79)
CodeMeaning
1Lock Monitor15Tub Water Thermistor Invalid17Dry Load Sense Timeout18Drain Pump Clearing Algorithm Failed19UI State Timeout2Door Monitor20Critical Flood Level by Gallons203Compressor Motor Inverter Fault206Compressor Motor Inverter Fault209Compressor Motor Inverter Fault215Compressor Motor Inverter Fault216Compressor Motor Inverter Fault217Compressor Motor Inverter Fault22Out of Balance (OOB) during Dry Load Sense220Compressor Motor Inverter Fault229Compressor Motor Inverter Fault23Critical Door Lock Failure233Compressor Motor Inverter Fault24Door Logic Failure241Compressor Motor Inverter Fault25Pressure Sensor Dropout26Out of Balance (OOB) Ended Final Spin27Water Accessibility29Suds Lock Abatement Failure3Locked Rotor Monitor303Blower Motor Inverter Fault306Blower Motor Inverter Fault31Out of Balance (OOB) Fallback In Final Spin311Blower Motor Inverter Fault317Blower Motor Inverter FaultView all 79 error codes
318Blower Motor Inverter Fault319Blower Motor Inverter Fault32Critical Door Lock Failure: Can't Unlock Door322Blower Motor Inverter Fault33Drive Motor Inverter Fault331Blower Motor Inverter Fault335Blower Motor Inverter Fault34Drive Motor Inverter Fault340Blower Motor Inverter Fault343Blower Motor Inverter Fault35Accelerometer Fault350UI351Dry Cycle Water Level Fault352Compressor Discharge Overtemp353Critical Compressor Discharge Overtemp354Compressor Discharge Thermistor Fault (NTC 1)355Evaporator Thermistor Fault (NTC 2)356Compressor Suction Thermistor Fault (NTC 3)357Air Outlet Temperature Sensor Fault (NTC 4)358Air Inlet Thermistor Fault (NTC 5)359Multiple Thermistor Faults41Drive Motor Inverter Fault42Drive Motor Inverter Fault43Drive Motor Inverter Fault44Drive Motor Inverter Fault51Drive Motor Inverter Fault57Door Lock Fault Water Above Door by Pressure59Accelerometer Fault6Critical Flood Level by Pressure60Accelerometer Fault61Accelerometer Fault63Accelerometer Fault64Accelerometer Fault65Pressure Sensor Continuous Gallons Monitor66Drive Motor Inverter Fault67Drive Motor Inverter Fault68Drive Motor Inverter Fault69Drive Motor Inverter Fault71Drive Motor Inverter Fault77Critical Door Lock Failure: Can't Unlock Door8Pressure Sensor Loss83Drive Motor Inverter Fault87Accelerometer Fault88Accelerometer Fault89Accelerometer Fault9Door Switch Redundancy90Accelerometer Fault91UI99Wifi Communication Fault
Service modes (2)
- Consumer Fault Code Mode (CFCM)From an idle state only (all LEDs off), press and hold the START pad for 10 seconds
- Service ModePress and hold the SmartDispense Detergent button, then the Timed Dry button (do not release), then…
Full entry steps, exit procedures, and test sequences are available in Max.