Electrolux Dryer Error Code 73

NTC2 open error

NTC2 open error — NTC open or disconnected.

First step from the service manual

Check NTC2 connection; if wiring is good, suspect main board fault.

The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.

MyPros+ Max

Get the full diagnostic procedure for 73.

  • Step-by-step tests with expected resistance, voltage, and continuity values
  • Wiring diagram references and connector pinouts from the OEM service manual
  • Verified part numbers when replacement is required
Get the full procedure

$29/month · Cancel anytime · Or $9.95 3-day pass

What 73 means on a Electrolux dryer

Error code 73 on an Electrolux dryer indicates an NTC2 open circuit fault. NTC stands for Negative Temperature Coefficient, referring to a thermistor that changes its electrical resistance in response to temperature changes. NTC2 is the second temperature sensor in the dryer's thermal monitoring system, and an "open" condition means the control board is detecting no signal from this sensor, as if the circuit has been broken or the sensor itself has failed. This prevents the dryer from accurately monitoring temperatures in the drum or exhaust path, triggering the fault to protect against potential overheating.

The most likely cause is a physical disconnection in the NTC2 wiring harness, such as a loose connector, a broken wire, or a connector that has vibrated free from the sensor or board terminal. This is the first thing to inspect: trace the NTC2 wiring from the sensor body to its connector on the main control board, checking for any obvious damage, corrosion, or separation at the terminals. If the wiring and connectors appear intact and secure, the thermistor itself may have failed internally, presenting an open circuit even though the physical connection looks fine.

If the wiring harness is confirmed to be in good condition and the NTC2 sensor tests as open or outside its expected resistance range when measured with a multimeter, the sensor must be replaced. However, if a new or known-good sensor still produces the error code after installation, attention should shift to the main control board, which may have a faulty input circuit for the NTC2 signal. Board-level faults in this context are less common than sensor or wiring issues but do occur.

Source: manufacturer service documentation.

Common causes of 73

  1. 01

    Loose or disconnected NTC2 connector

    Wiring / connection

    Vibration during normal operation can cause the wiring harness connector at the NTC2 sensor or the main control board to loosen or pull free. Inspect both ends of the NTC2 wiring harness for any disconnected or partially seated connectors.

  2. 02

    Broken or damaged NTC2 wiring

    Wiring / connection

    A wire in the NTC2 circuit may have broken internally or at a stress point, interrupting the signal even if connectors appear seated. Use a multimeter in continuity mode to test the full length of the NTC2 wiring harness.

  3. 03

    Failed NTC2 thermistor

    Part replacement

    The thermistor itself can fail in an open-circuit state, producing no readable resistance. Testing the sensor directly with a multimeter will show either infinite resistance or no continuity if the component has failed internally.

  4. 04

    Corroded or burned connector terminals

    Wiring / connection

    Heat and moisture can corrode the NTC2 connector terminals, increasing resistance to the point where the board reads the circuit as open. Inspect the connector pins closely for discoloration, oxidation, or heat damage.

  5. 05

    Faulty main control board

    Part replacement

    If the NTC2 wiring and sensor both test as good, the input circuit on the main control board responsible for reading the NTC2 signal may have failed. This is the least common cause and should only be suspected after all other components have been ruled out.

See the test procedure for each cause

Frequently asked questions about 73

What does 73 mean on a Electrolux dryer?
Error code 73 means the dryer's control board is detecting an open circuit on the NTC2 temperature sensor. NTC2 is a thermistor that monitors temperature during the drying cycle, and an open condition means the board is receiving no signal from it. This can be caused by a disconnected wire, a failed sensor, or in less common cases, a fault on the main control board itself. The dryer will not operate normally until the fault is resolved.
Can I fix error code 73 on my Electrolux dryer myself?
If you are comfortable working with appliances, the first step is to check whether the NTC2 sensor's wiring connector has simply come loose, which requires no tools beyond access to the dryer's interior. Testing the sensor and wiring with a multimeter is also within reach for a knowledgeable DIYer. Replacing the sensor is a straightforward part swap in most cases. However, if the fault traces back to the main control board, professional repair is recommended.
Is it safe to use my Electrolux dryer when error code 73 appears?
You should not continue using the dryer while error code 73 is active. The NTC2 sensor is part of the thermal monitoring system that prevents overheating, and operating without a functioning sensor removes an important safety protection. Running the dryer in this condition could lead to excessive heat buildup or damage to other components.
How much does it cost to repair error code 73 on an Electrolux dryer?
If the fix is simply reseating a loose connector, there is no parts cost involved. Replacing an NTC thermistor sensor is generally a low-cost repair, with parts typically ranging from $15 to $50 depending on the specific model. If the main control board is at fault, that repair is significantly more expensive, with parts alone ranging from $100 to $300 or more, plus any labor costs if a technician is involved.
Will resetting my Electrolux dryer clear error code 73?
A reset may temporarily clear the error code display, but the code will return as soon as the dryer attempts to read the NTC2 sensor again and finds the circuit still open. Resetting does not repair a faulty sensor, broken wire, or disconnected connector. The underlying fault must be diagnosed and corrected before the error will stay cleared permanently.